Compact Cylinder: Standard Type, Double Acting, Double Rod CQ2W Specifications – Xi Lanh Khí Nén SMC
Compact Cylinder: Standard Type, Double Acting, Double Rod CQ2W Series image
JIS symbol
Without cushion / rubber bumper
Pneumatic Type
| Tube Inner Diameter (mm) |
12 |
16 |
20 |
25 |
32 |
40 |
50 |
63 |
80 |
100 |
| Action |
Double acting, double rod |
| Fluid |
Air |
| Proof Pressure |
1.5 MPa |
| Maximum operating pressure |
1.0 MPa |
| Minimum operating pressure |
0.07 MPa |
0.05 MPa |
| Ambient and Fluid Temperature |
Without auto switch: -10°C to 70°C (No freezing)
With auto switch: -10°C to 60°C (No freezing) |
| Lubrication |
Not required (non-lubricated) |
| Piston Speed |
50 to 500 mm/s |
| Allowable kinetic energy J |
Standard Type |
0.022 |
0.038 |
0.055 |
0.09 |
0.15 |
0.26 |
0.46 |
0.77 |
1.36 |
2.27 |
| Rubber bumper |
0.043 |
0.075 |
0.11 |
0.18 |
0.29 |
0.52 |
0.91 |
1.54 |
2.71 |
4.54 |
| Stroke Length Tolerance |
(0 to +1.0 mm)* |
*The stroke length tolerance does not include changes to the bumper.
Air-hydro type
| Tube Inner Diameter (mm) |
20 |
25 |
32 |
40 |
50 |
63 |
80 |
100 |
| Action |
Double acting, double rod |
| Fluid |
Turbine oil* |
| Proof Pressure |
1.5 MPa |
| Maximum operating pressure |
1.0 MPa |
| Minimum operating pressure |
0.18 MPa |
0.1 MPa |
| Ambient and Fluid Temperature |
5 to 60°C |
| Piston Speed |
5 to 50 mm/s |
| Cushioning |
None |
| Stroke Length Tolerance |
(0 to +1.0 mm) |
*Use petroleum based hydraulic turbine oil for the hydraulic fluid. The use of an incombustible hydraulic fluid may result in problems.
The operating temperature range for ISO VG32 is 15 to 35°C. If operating at a temperature range above that of ISO VG32, use ISO VG46 (25 to 45°C).